Cobra Controls ACP-2N Series Computer Access Controller
Overview
Door access control with built in TCP/IP Ethernet hookup. The ACP series from Cobra Controls allows you to connect an unlimited number of 1, 2 or 4 door panels to your network for complete system expansion. Cobra controllers use NON-PROPRIETARY readers and inputs based on the industry standard Wiegand format.
Click Here for Software Setup Video
We can assist you with system design including lock selection. For assistance configuring this controller or any of our computerized kits please Call us Toll Free at 1.866.500.5625 or use the Live Chat feature.
An upgraded power supply (ACP-NF Series) will provide a fire-panel tie-in and allow maglocks to be released in the event of a fire alarm. The additional power is required when powering 4 or more maglocks. For more details please call 1.866.500.5625.
ACP-N Series Controllers are not compatible with ACP-T Series Controllers.
Product Details
N-Series Software Not Compatible with T-Series Controllers
Product Overview
Access control with built in TCP/IP Ethernet interface. The ACP series from Cobra Controls allows you to connect an unlimited number of 1, 2 or 4 door panels to your network for complete system expansion. Cobra controllers use NON-PROPRIETARY readers and inputs based on the industry standard Wiegand format. ACP-N Series Controllers are not compatible with ACP-T Series Controllers.
Models
- ACP-4N (4-Door Controller: 2 AMP)
- ACP-2N (2-Door Controller: 2 AMP)
- ACP-1N (1-Door Controller: 2 AMP)
- ACP-4NF (4-Door Controller: 4 AMP)
- ACP-2NF (2-Door Controller: 4 AMP)
- ACP-1NF (1-Door Controller: 4 AMP)
Features
- Easily add or remove card holders with only a few mouse clicks
- 255 time zones with start and stop dates
- Individual door sensor/monitoring inputs for each door
- Individual request to exit RTE inputs for each door
- Lost card registry with simple reissue feature
- Unlimited departments and sections
- Unlimited number of control panels and doors on same system
- Audit trail customizable by date, department, user, and/or by door. Report layout also flexible. Save as Excel spreadsheet, print, or view.
- Industry standard 26 bit Wiegand interface to work with any combination of Card readers, keypads, fingerprint reader, bar-code reader, etc. with Wiegand output.
- Real time monitoring through software for alarms, duress, invalid card reads, door propped, and door forced events.
- Anti-pass back
- Storage capacity: 20,000 users and 100,000 events
Real Time Monitoring
- The Cobra Controls .net Access Control Software also offers a powerful real time monitoring and management interface. Watch as the computer scans doors and reacts to real time events.
- Note: Live connection to controllers not required for doors to operate - needed only for live interaction. Features of real time monitoring screen:
- Check command performs status and diagnostics on selected doors and their controllers. Setting time synchronizes controllers to the computer for timing. Upload and download from this interface to update both the controller with correct access privileges and to receive latest auditing information. A real-time download option keeps you up to the second with event monitoring.
- Remote locking and unlocking of any one or all doors is a simple mouse click. You can "lock down" or lock open any one or multiple doors. Momentary unlock a door and then it will go back to normal access state. Reset alarms via mouse.
Specifications
- 12VDC 2AMP Linear Power Supply in locking metal enclosure with outputs for control panel and electronic locks included
- 16.5 VAC Transformer included
- Locking Metal Enclosure included 12.0" x 13.0" 3.9"
ACP-N Series Computerized Access Control
Function Introduction | |
Conventional Function | Offline operation; real time supervision; photo display; mass storage; flexible user privilege setup; remote unlocking; multi-user supervision; quick setting; convenient checking and query; revisable and printable report form; report form; report can be exported to excel file; card+password unlocking; alarm for long time unclosing; alarm for invalid card swiping; first card unlocking; alarm for illegal break in; unlocking at definite time; e-map etc. |
Professional function | For professional users such as bank, cash house, telecom station, power supply station, prison and police station: interface locking; intimidation alarm; integrated fire control; anti-passback and anti-tail; interlocking; multi-card unlocking; emergency double locking; in door population checking; unlocking based on internal and external validation. |
all-in-one-card management system | normal shift and multi-shifts time attendance management system; fixed ration dining management system; meeting attendance management system; online patrol management system and security alarm management system. |
Parameter | |
Communication | TCP/IP 10M/100M adaptive |
English Software supportable database | Access and SQL |
Description | Control 1, 2 or 4 door, get in and out door by swiping card, or get in by swiping card and get out door by button |
Power Supply | 12VDC, 2amp supply standard. (12VDC, 4amp supply with fire panel tie in available) |
Power Consumption of Circuit Board | Less than 100mA |
Input Format of Reader | Wiegand 26 (All card reader with compatible protocol, such as Motorola , HID® (H10301), EM , Mifare one etc.) |
Quantity of Readers | 2 readers per door |
Door Controlled | Boards available for 1,2 or 4 door. |
Door opening time extending setting | 1-600 seconds (adjustable) |
Max Quantity of controller | N = No limit |
Remark: N denotes quantity of computer serial port or quantity of 485 hub port, support 256pcs ports | |
Operation Temperature | minus 40 - plus 70 |
Operation Humidity | 10-90 % RH - No Condensation |
Quantity of users | 20,000 Users |
Quantity of Event Buffers (offline) | 100,000 event buffers |
Power interruption protection measure | High Speed Memory, Records never lose |
Max Distance from Reader to Controller | 100m (suggestion distance 80m) |
Max Distance between Controllers | RS232: Communication Distance less than 13m, suggestion distance is 3m or less |
RS485: bus line max length 1200m, suggestion length 1000m or less, if expansion device added, the distance could be 3000m | |
TCP/IP: Depends on net coverage area | |
Collocations | PCB board, case, power, power line, serial port communication line, software, manual, certificate, key(2pcs), carton |
Alarm for long time door open, illegal break in, intimidate | Yes |
Fire and alarm linkage | If no connection with the expansion board, only has software interface alarm, and drive the computer speaker. If connected with expansion board, is able to alarm by hardware, if connected with strengthened expansion board, then is able to Security alarm |
Compulsive open and close door at long time | Yes |
Open door in remote distance | Yes |
Inter lock | Yes |
Anti pass back and tail | Yes |
Multi-card open door | Yes |
Open long time at specified time | Yes |
Electronic map | Yes |
Urgency locking | Yes |
First card unlocking | Yes |
Unlock based on internal and external validation | Yes |
Keypad (card+password, super password) | Yes |
Copyright 2018, Cobra Controls. All rights reserved.